Informations
|
Manufacturier |
Tripp Lite |
No Manufacturier (p/n) |
SMART1200XLHG |
Ligne de produit |
SmartPro |
Catégorie |
Line-interactive UPS |
Informations techniques
|
Type de connecteur |
NEMA 5-15P |
Prises |
4 x NEMA 5-15R |
Longueur du cordon |
6 ft |
Temps de commutation |
4 ms |
Alimentation
|
Capacité de charge (VA) |
1000 VA |
Capacité de charge (Watt) |
750 W |
Tension (entrée) |
110 V AC |
Tension de sortie |
120 V AC |
Management
|
Gestion de réseau |
SNMP Manageable |
Alarme |
On Battery, Overload, Low Battery |
contrôles et indicateurs
|
Indicateurs d'état |
Includes 5 front-panel indicator LEDs to show battery charge level, AC line voltage levels, automatic voltage regulation status, UPS load level and replace battery warning |
Ports
|
USB |
Oui |
Informations sur la batterie
|
Chimie de la batterie |
Sealed Lead Acid |
Autonomie (pleine charge) |
16 Minute |
Autonomie (demi charge) |
34 Minute |
Autonomie de la batterie |
6 ans |
Temps de recharge maximum de la batterie |
4 Hour |
Remplaçables à chaud |
Oui |
Conditions environnementales
|
Température |
104°F (40°C) |
Caractéristiques physiques
|
Hauteur |
12.8" (323.9 mm) |
Largeur |
7.5" (190.5 mm) |
Profondeur |
9" (228.6 mm) |
Forme (Form Factor) |
Tower |
Poids (aproximatif) |
20.23 kg |
Divers
|
Contenu de la boîte |
- SmartPro 1200XLHG UPS
- SMART 1200XLHG Medical Grade Tower UPS System
- PowerAlert Software and cabling
- Warranty information
- Instruction manual
|
Informations Complémentaires |
- Ideal UPS protection for applications in medical patient-care areas where UL 2601-1 listed medical electrical equipment is required
- Maintains less than 300 microamps leakage current for UPS and all connected equipment
- Built-in isolation transformer with faraday shield offers full isolation and removes common mode noise while maintaining full AC surge suppression in all modes
- Provides connected equipment with continuous power during short and long duration loss of commercial power
- Expandable runtime is available with the addition of one or more external battery packs (part# BP36V27)
- Line-interactive voltage regulation corrects brownouts and overvoltages from 81 to 143 volts back to usable 120V output levels, without using battery power
- Hospital-grade plug and outlets offer added degree of safety and reliability to input/output connections
- Full line isolation prevents shock potential and operational problems in sensi
|
Certifications et standards |
UL1778 (USA, Series AGSM1200PSR3HG), UL2601-1 (Medical), cUL (Canada), FCC Class A (emissions), Conforms to IEEE 587 / ANSI C62.41 specifications |
Garantie
|
Garantie limitée |
2 ans |