Informations
|
Manufacturier |
Tripp Lite |
No Manufacturier (p/n) |
SU10000RT3U |
Ligne de produit |
SmartOnline |
Modèle |
SU10000RT3U |
Catégorie |
Dual Conversion Online UPS |
Informations techniques
|
Type de connecteur |
Hardwired |
Prises |
2 x NEMA L6-30R, 4 x NEMA L6-20R |
Temps de commutation |
0 ns |
Alimentation
|
Capacité de charge |
10 kVA/8 kW |
Tension (entrée) |
220 V AC |
Plage de tension d'entrée |
208 V AC, 230 V AC, 240 V AC, 200 V AC |
Tension de sortie |
200 V AC User Selectable, 220 V AC User Selectable, 208 V AC Nominal, 230 V AC User Selectable, 240 V AC User Selectable |
Fréquence |
50 Hz, 60 Hz |
Type de forme d'onde |
Sine Wave |
Filtration |
EMI / RFI |
Évolutivité
|
Modules |
Power Module, Battery Module |
Management
|
Gestion de réseau |
SNMP Manageable Optional |
Alarme |
Backup Operation, Low Battery, Output Overload, Imminent Shutdown, Inverter Fault, DC Bus Fault, Over Temperature, Remote Shutdown, Shutdown Complete, UPS Start |
Commutateur de dérivation (ByPass) |
Manual |
Arrêt d'urgence automatique |
Oui |
contrôles et indicateurs
|
Indicateurs d'état |
LED Display:
- Line power
- Bypass
- Inverter
- Charger
- Output AC
- Battery operation
|
Informations sur la batterie
|
Batteries |
User Replaceable Hot-swappable |
Temps de sauvegarde |
0.10 Hour 8 kW Full Load, 0.20 Hour 4 kW Half Load |
Autonomie de la batterie |
35063.25 Hour to 52594.88 Hour |
Temps de recharge de la batterie |
8 Hour |
Conditions environnementales
|
Température |
32°F (0°C) to 104°F (40°C) Operating, 5°F (-15°C) to 122°F (50°C) Storage |
Humidité |
0 to 95% Non-condensing Relative Humidity |
Thermal Dissipation |
3022 BTU/h |
Cooling Type |
Fan |
Caractéristiques physiques
|
Couleur |
Noir |
Forme (Form Factor) |
6U Tower/Rack Mountable |
Divers
|
Contenu de la boîte |
- Smart Online, SU10000RT3U, Expandable 10kVA Tower/Rack-mountable UPS System
- 3U power module with detachable hot-swap PDU input/output panel and bypass switch
- 3U external battery pack
- Two sets of 4-post rackmount rails (one for each of the 3U components)
- One set of tower stands for upright tower con
|
Informations Complémentaires |
- Switches: Includes main power off/on switch, plus 2 switches to set and execute scrollable LCD functions
- Low voltage transfer to battery power: Maintains continuous operation during undervoltages as low as 156VAC, below this point, output is maintained utilizing battery reserves
- High voltage transfer to battery power: Maintains continuous operation during overvoltages to 276V AC, above this point, output is maintained utilizing battery reserves
- Cold Start: Yes, inverter can be "cold started" to enable temporary AC output during a power failure
- Voltage regulation description: On-line, double-conversion process give this UPS the ability to maintain output voltage within +/-2% of selected nominal voltage at all times
|
Certifications et standards |
Tested to UL1778 (USA), CSA (Canada), CE (European Union), NOM (Mexico), Class A (Emissions) |
Logiciels inclus |
PowerAlert Software |
Garantie
|
Garantie limitée |
2 ans |